Marley NC Fibra de vidrio

Torre de refrigeración de contracorriente

The Marley® NC Fiberglass Cooling Tower provides operators with the corrosion resistance of fiberglass, a strong steel support structure y Marley-engineered components. This industrial-strength cooling tower product gives customers the integrityperformancereliability they expect for demanding HVAC and industrial applications.

Available in numerous box sizes – factory assembled or field erected – the Marley NC Fiberglass tower offers cooling capacities ranging 450-6400 kW (1455 nominal tons) per cell at standard CTI conditions.

Photo of a Marley NC Fiberglass cooling tower
Certificaciones
CTI Certified, Eurovent Certified, ASHRAE 90.1 compliant, CE / OSHA Compliant
Montaje
Montado en fábrica o desmontado para montaje en obra
Disponibilidad
Available in APAC, Europe, Middle East and Africa
Rango GPM
303-4461 gpm per cell (69-1013 m3/hr)
Capacidad térmica
101-1487 tons per cell (444-6537 kW)
Detalles y características

Less Maintenance, Less Downtime
The Marley NC Fiberglass Cooling Tower can stay online while maintained; pumps can remain operational during cleaning and inspections of the distribution system. The tower’s crossflow design and large access doors promote easy access.

Robust Design for Long Service Life
Wetted components of fiberglass reinforced polyester (FRP) perform reliably in hot, moist cooling tower confines. Steel support structure options include hot-dip galvanized steel, 304 stainless steel and 316 stainless steel to help withstand exposure to harsh environments.

Third-Party Certified for Performance & Sound
Each model is tested and certified by the Cooling Technology Institute (CTI) and Eurovent for guaranteed thermal performance. Sound levels are also independently verified by a CTI-licensed test agency and acoustic engineer.

Low Energy, Low Operating Costs
Highly efficient Marley fill and fans, gravity-flow water distribution, and mechanical drive systems work together to maximize cooling while conserving fan power. Mechanical components include a five-year warranty and the Marley Geareducer® gear drive requires no maintenance for the first five years.

All Season Performance
The NC Fiberglass Cooling Tower is reliable in the heat of summer and adaptable to energy management techniques such as variable flow and “free cooling” in the shoulder seasons. Its integral louvers help protect against ice buildup in the dead of winter.

Custom Options Available
Multiple upgrades can be made to an NC Fiberglass Cooling Tower based on your needs, including options for the air movement package, the water distribution system and the tower structure.

Descargas
Download the document: Marley NC Fiberglass Cooling Tower
Marley NC Fiberglass Cooling Tower
Download the document: Marley NC Fiberglass User Manual
Marley NC Fiberglass User Manual
Download the document: Marley NC Fiberglass Engineering Data and Specifications
Marley NC Fiberglass Engineering Data and Specifications

Asistencia real de un equipo real

EMEA Cooling Tower Customer 2 (1)

Nuestros clientes hablan: escuche lo que dicen:

"Las torres de refrigeración y las soluciones HVAC de Marley son de primera categoría, con una fiabilidad y eficiencia inigualables. El equipo de atención al cliente es profesional, receptivo y va más allá para garantizar la satisfacción".

Recomiendo encarecidamente SPX Marley por su excelente rendimiento y dedicación".

"Cambiar a un producto diseñado por Marley / SPX ha sido la mejor decisión que podíamos haber tomado. El producto nos ha proporcionado la fiabilidad que necesitábamos pero que no obteníamos de nuestro antiguo equipo".
"Un equipo muy accesible con excelentes conocimientos y experiencia".

es_MXSpanish