Marley NC Fiberglass

Counterflow Cooling Tower

The Marley® NC Fiberglass Cooling Tower provides operators with the corrosion resistance of fiberglass, a strong steel support structure et Marley-engineered components. This industrial-strength cooling tower product gives customers the integrityperformanceet reliability they expect for demanding HVAC and industrial applications.

Available in numerous box sizes – factory assembled or field erected – the Marley NC Fiberglass tower offers cooling capacities ranging 450-6400 kW (1455 nominal tons) per cell at standard CTI conditions.

Photo of a Marley NC Fiberglass cooling tower
Certifications
CTI Certified, Eurovent Certified, ASHRAE 90.1 compliant, CE / OSHA Compliant
Assemblée
Factory Assembled or Knocked Down for Site Assembly
Disponibilité
Available in APAC, Europe, Middle East and Africa
Gamme de GPM
303-4461 gpm per cell (69-1013 m3/hr)
Capacité thermique
101-1487 tons per cell (444-6537 kW)
Détails et caractéristiques

Less Maintenance, Less Downtime
The Marley NC Fiberglass Cooling Tower can stay online while maintained; pumps can remain operational during cleaning and inspections of the distribution system. The tower’s crossflow design and large access doors promote easy access.

Robust Design for Long Service Life
Wetted components of fiberglass reinforced polyester (FRP) perform reliably in hot, moist cooling tower confines. Steel support structure options include hot-dip galvanized steel, 304 stainless steel and 316 stainless steel to help withstand exposure to harsh environments.

Third-Party Certified for Performance & Sound
Each model is tested and certified by the Cooling Technology Institute (CTI) and Eurovent for guaranteed thermal performance. Sound levels are also independently verified by a CTI-licensed test agency and acoustic engineer.

Low Energy, Low Operating Costs
Highly efficient Marley fill and fans, gravity-flow water distribution, and mechanical drive systems work together to maximize cooling while conserving fan power. Mechanical components include a five-year warranty and the Marley Geareducer® gear drive requires no maintenance for the first five years.

All Season Performance
The NC Fiberglass Cooling Tower is reliable in the heat of summer and adaptable to energy management techniques such as variable flow and “free cooling” in the shoulder seasons. Its integral louvers help protect against ice buildup in the dead of winter.

Custom Options Available
Multiple upgrades can be made to an NC Fiberglass Cooling Tower based on your needs, including options for the air movement package, the water distribution system and the tower structure.

Téléchargements
Download the document: Marley NC Fiberglass Cooling Tower
Marley NC Fiberglass Cooling Tower
Download the document: Marley NC Fiberglass User Manual
Marley NC Fiberglass User Manual
Download the document: Marley NC Fiberglass Engineering Data and Specifications
Marley NC Fiberglass Engineering Data and Specifications

Une véritable assistance de la part d'une véritable équipe

EMEA Cooling Tower Customer 2 (1)

Nos clients parlent - Écoutez ce qu'ils ont à dire :

"Marley cooling towers and HVAC solutions are top-notch, with unmatched reliability and efficiency. The customer service team is professional, responsive, and goes above and beyond to ensure satisfaction.

I highly recommend SPX Marley for their outstanding performance and dedication."

"Switching to an Marley / SPX engineered product has been the best choice we could’ve made. The product has provided us with the reliability that we needed but weren’t getting from our old equipment."
"A very approachable team with excellent knowledge and expertise.”

fr_FRFrench